Application
The Anesthesia machine makes a good performance in Intensive Care Units (ICU), Operation room, Anesthesiology Department and other departments.
Professional design for adult, child and infant inhalation anesthesia and respiratory management, with advanced ventilation modes.
Outstanding ergonomic design, it ranks high level in safty, stability and convenience as well as user experiences.
S6100 comfortable classic model, easy to use and be designed together with experienced experts to streamline your anesthesia workflow.
Trustpoint
-
Simplicity: 4 static casters with self-locking function.
-
Precision in an anesthesia ventilator with multiple ventilation modes: IPPV, A/C, PCV, SIMV, SIGH and MANUAL.
-
Flexible configurations able to customize your requirements.
-
International standard and advanced technology suitable for wide range use.
-
Compact interface and big screen give you better operating experience.
-
Over 5,000 units are installed in more than 200 countries.
-
Designed and manufactured by Superstar Medical with over 25 years of experience in ICU field.
Feature
-
10.4” TFT LCD screen displays the Ventilation parameters, Alarm information and Oscillogram.
-
High precision flowmeter, instantly know the fresh gas flow to your patient.
-
Integrated breathing circuit design, ensure easy operating and keep tidy.
-
Multiple working modes such as volume control and pressure limit, adapt to wide range patient.
-
Vaporizer with temperature, pressure, flow compensation and self-lock function, keep safety anytime.
-
Multiple parameters monitoring interface, make every parameter clear, let users know the patient conditions in all aspects.
-
Pressure-time, low-time loop oscillogram and high precision ETCO2, O2 concentration show in real time.
-
Vital sign monitor and anesthetic gas monitor are optional.
-
ETCO2 module and Anesthesia Gas Scavenging System (AGSS) are optional.
Safety
-
3 level alarm system, visual and sound alarm information.
-
With multiple type of alarm, reminder and protection functions.
-
Advanced power management control technology.
-
Built-in backup battery provide the emergency power supply to the unit.
-
Low O2 pressure alarm and N2O cut-off protection
Specifications
Ventilation modes:
IPPV; A/C; PCV; SIMV; SIGH; MAUN
Ventilator parameter ranges
Flow meter
O2(0.1-10L/min)
N2O(0.1-10L/min)
AIR(0.1-10L/min)
Rapid oxygen supply
35L/min-75L/min
Tidal volume(Vt)
0, 20 mL ~ 1500 mL
Frequence(Freq)
1bpm ~ 100 bpm
I/E
4:1~1:8
PEEP
0cmH2O ~ 30 cmH2O
Pressure triggering sensitivity(PTr)
-20 cmH2O ~ 0 cmH2O(Based on PEEP)
Flow trigger sensitivity (FTr)
0.5 L/min ~ 30 L/min
Pressure control (PC)
5 cmH2O ~ 60 cmH2O
SIGH
0(off) 1/100 ~ 5/100
Apnea Ventilation
OFF,5 s ~ 60 s
Pressure Limit
20 cmH2O ~ 100 cmH2O
Monitored Parameters
Frequence(Freq)
0 /min ~ 100 /min
Tidal volume(Vt)
0 mL ~ 2000 mL
MV
0 L/min ~ 100 L/min
Oxygen concentration
15 % ~ 100 %
Graphical display:
P-T(pressure – time)
F-T(flow – time)
P-V loop (pressure – volume loop)
Size
Wooden case packing size:L 770*W 890*H 1535mm , GW:151KG ; NW:91.2KG
Alarm and protection
The AC power failure alarm
Power failure or no connection
Internal battery backup low voltage alarm
<11.3±0.3V
No tidal volume
≤5Ml within 6s
High oxygen concentration alarm
Low oxygen concentration alarm
19%-100%
18%-99%
High Airway pressure alarm
Low Airway pressure alarm
High Minute Volume alarm
Low Minute Volume alarm
Continuous Pressure alarm
20cmH2O-100cmH2O
0cmH2O-20cmH2O
Adult(5L/min-20L/min) Paed(1L/min-15L/min
0-10L/min)
(PEEP+1.5kPa) over 16s
Suffocation warning
5s-60s no spontaneous ventilation
The maximum limited pressure
<12.5 kPa
Fan error
Oxygen deficit
Show on screen
Show on screen
Working conditions
Gas source
O2,N2O,AIR
Pressure
280kPa-600kPa
Voltage
100-240V
Power frequency
50/60Hz
Input power
85VA
Vaporizer
Anesthesia gas
Adjustable scope % (volume percentage)
Halothane
0 ~ 5
Enflurane
0 ~ 5
Isoflurane
0 ~ 5
Sevoflurane
0 ~ 8